Resolves a number of issues, except for the clen function being
unused on Linux, as that would require a larger refactor which
probably isn't strictly necessary.
$ staticcheck .
affinity_linux.go:94:8: const m3 is unused (U1000)
affinity_linux.go:95:8: const m4 is unused (U1000)
sendfile_test.go:41:2: the goroutine calls T.Fatal, which must be called in the same goroutine as the test (SA2002)
sendfile_test.go:47:6: this value of err is never used (SA4006)
syscall_linux_test.go:519:21: should use time.Since instead of time.Now().Sub (S1012)
syscall_linux_test.go:530:21: should use time.Since instead of time.Now().Sub (S1012)
syscall_test.go:66:2: this value of ts is never used (SA4006)
syscall_test.go:67:2: this value of ts is never used (SA4006)
syscall_unix.go:88:6: func clen is unused (U1000)
Change-Id: I2611b4559339cea758b5da27ea1f36fb8cc2df3f
Reviewed-on: https://go-review.googlesource.com/c/sys/+/188037
Run-TryBot: Matt Layher <mdlayher@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
This adds wrappers around name_to_handle_at and open_by_handle_at.
Requires root (or CAP_DAC_READ_SEARCH, rather) to run tests, which at
least some of our builders have.
bradfitz@go:~/src/golang.org/x/sys/unix$ go test -c && sudo ./unix.test -test.run=OpenBy -test.v=true
=== RUN TestOpenByHandleAt
=== RUN TestOpenByHandleAt/clone=false
=== RUN TestOpenByHandleAt/clone=true
--- PASS: TestOpenByHandleAt (0.00s)
syscall_linux_test.go:546: mountID: 22, handle: size=8, type=1, bytes="\x9e\x1e\b\x00~\x8c\xe5\x9d"
--- PASS: TestOpenByHandleAt/clone=false (0.00s)
syscall_linux_test.go:568: opened fd 3
--- PASS: TestOpenByHandleAt/clone=true (0.00s)
syscall_linux_test.go:568: opened fd 3
PASS
Fixesgolang/go#30537
Change-Id: Ia48a8faab2fee665d88a16d81a3a0c1504b129ce
Reviewed-on: https://go-review.googlesource.com/c/sys/+/173357
Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
If a system has the ability to disable some cores, as on
ppc64 with the ppc64_cpu command, then TestSchedSetaffinity will
fail if the CPUset passed to Setaffinity includes one that has
been disabled.
This adds a check to use values from the oldMask, which are the valid
cores returned from Getaffinity, to pass to Setaffinity.
Fixesgolang/go#27875
Change-Id: I9656f41867afc18e0eaedc4bdef5f75e137a1fcd
Reviewed-on: https://go-review.googlesource.com/137675
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
The Linux kernel faccessat system call does not take a flags parameter.
The flag parameter to the C library faccessat function is implemented in C.
The unix.Faccessat function takes a flags parameter. In older releases
we have passed the flags parameter to the kernel, which ignored it.
In CL 119495 we started returning an error if any flags were set.
That seems clearly better than ignoring them, but it turns out that some
code was using the flags. The code was previously subtly broken.
Now it is obviously broken. That is better, but we can do better still:
we can implement the flags as the C library does. That is what this CL does.
Change-Id: I02d4bb981ebd39eb35e47c6e5281f85eaea68016
Reviewed-on: https://go-review.googlesource.com/126516
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
If the underlying filesystem doesn't support atime or was mounted with the
noatime mount option, TestUtimesNanoAt fails when comparing atime:
--- FAIL: TestUtimesNanoAt (0.00s)
syscall_linux_test.go:144: UtimesNanoAt: wrong atime: {1111 0}
syscall_linux_test.go:147: UtimesNanoAt: wrong mtime: {3333 0}
FAIL
FAIL golang.org/x/sys/unix 0.376s
Fix it by dropping the atime comparison, it's enough to verify UtimesNanoAt
working correctly by comparing mtime.
Fixesgolang/go#26034
Change-Id: Id868f9d4c6a856a99ae930a46bfe91bd64ca8570
Reviewed-on: https://go-review.googlesource.com/120562
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
On some builders TestStatx occassionally fails when comparing atime
between Statx and Stat/Lstat.
--- FAIL: TestStatx (0.00s)
syscall_linux_test.go:365: Statx: returned stat atime does not match Lstat
Fix it by dropping the atime comparison, it's enough to verify Statx
working correctly by comparing ctime and mtime. Also, not all
filesystems support atime.
Change-Id: I7da68bd20b9b21274c4993aa2c4241395d2c933a
Reviewed-on: https://go-review.googlesource.com/114616
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
The mkfifo syscall is disallowed on android and iOS. sched_setaffinity
is disallowed on android. Skip all tests which use them.
/usr/bin does not exist on android. Use /system/bin in TestGetwd
instead, like TestChdirAndGetwd in the os package.
Like linux, android does not support Fchmodat with flags != 0. Adjust
TestFchmodat accordingly.
TestDevices might stat some device files which are not accessible, skip
those.
iOS cannot exec subprocesses, thus skip TestPassFD.
Fixesgolang/go#25535
Change-Id: Ic764b9152f0a7b703ad4f47fdb1a9a5e94718154
Reviewed-on: https://go-review.googlesource.com/114395
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Now that Fchmodat is available on all Unices, move TestFchmodat to
syscall_unix_test.go and adjust it such that Fchmodat with
AT_SYMLINK_NOFOLLOW in flags is tested where supported.
Change-Id: I41ef5b874e36d84ed4866706dbba075c39aa00d4
Reviewed-on: https://go-review.googlesource.com/101615
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
statx(2) allows to get enhanced file status information (not currently
available through the existing stat syscalls), lightweight stat,
heavyweight stat. The Statx_t type used by Statx has consistent field
sizes on all arches (with year-2038-capable timestamps) and is closer to
the BSD implementation of Stat_t.
See http://man7.org/linux/man-pages/man2/statx.2.html for details. The
syscall was added in Linux kernel 4.11.
See https://github.com/tklauser/statx for an example of how this
function and types can be used to report stat(1)-like file status
information.
Change-Id: I9e9642b5b42a393f94fd532453888ce9ba4f0003
Reviewed-on: https://go-review.googlesource.com/87555
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Looks like it's enough to just add wrappers pointing to the
corresponding SYS_FSTATAT{,64} or SYS_NEWFSTATAT syscall. Add a test to
verify that assumption which checks that the returned stat data matches
what is returned by Stat/Lstat.
Also add the AT_NO_AUTOMOUNT constant which may be used for the flags
parmeter.
Fixesgolang/go#14216
Change-Id: I73f27b483bd97d2dcf09d4b95a7957e75d194395
Reviewed-on: https://go-review.googlesource.com/79795
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
In order to make conversion to string easier, change the Utsname
members from int8 array to byte array.
Also add a test on Linux for Uname and the string conversion of the
Utsname members.
Fixesgolang/go#20753
Change-Id: Iec793dfb4a6dd8f3523cf0b6284a6162074f2e9e
Reviewed-on: https://go-review.googlesource.com/74331
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Analog to the runtime package, Select should be using newselect
instead of select. This change addresses this problem and regenerates
zsyscall_linux_* for ppc64 and ppc64le.
Updates golang/go#21946
Change-Id: I7ed5c2490ba2ce556f143f8e8377572ab345f7b8
Reviewed-on: https://go-review.googlesource.com/65091
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Lynn Boger <laboger@linux.vnet.ibm.com>
Currently Linux' fchmodat(2) syscall implementation doesn't support the
flags parameter (though it might in future versions [1]). Fchmodat in
x/sys/unix takes the parameter and (wrongly) passes it on to the syscall
which will ignore it.
According to the POSIX.1-2008 manual page [2], AT_SYMLINK_NOFOLLOW is
the only valid value for the flags parameter and EOPNOTSUPP should be
returned in case changing the mode of a symbolic link is not supported
by the underlying system. EINVAL should be returned for any other value
of the flags parameter.
[1] https://patchwork.kernel.org/patch/9596301/
[2] http://pubs.opengroup.org/onlinepubs/9699919799/functions/chmod.html
Change the Fchmodat implementation accordingly and also add the
corresponding test.
Fixesgolang/go#20130
Change-Id: I62e677e6674d3702eaf388af0ac3d7e623a35c24
Reviewed-on: https://go-review.googlesource.com/46474
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
This CL adds basic integer get/set functions which wrap a generic
ioctl call. The API is similar the one introduced for solaris/amd64
in CL 14587, but the request parameter has been changed to a uint
instead of an int. This makes requests with a number larger than the
maximum signed 32-bit integer work on linux/386.
For consistency, the solaris/amd64 API has also been updated to make
use of a uint instead of an int for the request number.
Fixesgolang/go#20474
Change-Id: Iaae1ee2e4bb4bfcc420dcec252fe53c8d90ce81d
Reviewed-on: https://go-review.googlesource.com/44009
Run-TryBot: Matt Layher <mdlayher@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>